1. Name: ada1
   Mediasize: 5000981078016 (4.5T)
   Sectorsize: 512
   Stripesize: 4096
   Stripeoffset: 0
   Mode: r2w2e5
   descr: WDC WD50EFRX-68MYMN1
   lunid: 50014ee25fe5efa3
   ident: WD-WX41D3402672
   rotationrate: 5700
   fwsectors: 63
   fwheads: 16 

 

 

 

smartctl 6.6 2017-11-05 r4594 [FreeBSD 11.2-STABLE amd64] (local build)
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Western Digital Red
Device Model:     WDC WD50EFRX-68MYMN1
Serial Number:    WD-WX41D3402672
LU WWN Device Id: 5 0014ee 25fe5efa3
Firmware Version: 82.00A82
User Capacity:    5,000,981,078,016 bytes [5.00 TB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    5700 rpm
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ACS-2, ACS-3 T13/2161-D revision 3b
SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is:    Thu Dec 19 22:31:41 2019 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00)	Offline data collection activity
					was never started.
					Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(57180) seconds.
Offline data collection
capabilities: 			 (0x7b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   2) minutes.
Extended self-test routine
recommended polling time: 	 ( 571) minutes.
Conveyance self-test routine
recommended polling time: 	 (   5) minutes.
SCT capabilities: 	       (0x303d)	SCT Status supported.
					SCT Error Recovery Control supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x002f   200   200   051    Pre-fail  Always       -       0
  3 Spin_Up_Time            0x0027   198   196   021    Pre-fail  Always       -       9100
  4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       -       623
  5 Reallocated_Sector_Ct   0x0033   200   200   140    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x002e   200   200   000    Old_age   Always       -       0
  9 Power_On_Hours          0x0032   053   053   000    Old_age   Always       -       35024
 10 Spin_Retry_Count        0x0032   100   100   000    Old_age   Always       -       0
 11 Calibration_Retry_Count 0x0032   100   100   000    Old_age   Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       623
192 Power-Off_Retract_Count 0x0032   200   200   000    Old_age   Always       -       71
193 Load_Cycle_Count        0x0032   188   188   000    Old_age   Always       -       36743
194 Temperature_Celsius     0x0022   119   104   000    Old_age   Always       -       33
196 Reallocated_Event_Count 0x0032   200   200   000    Old_age   Always       -       0
197 Current_Pending_Sector  0x0032   200   200   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0030   100   253   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x0032   200   200   000    Old_age   Always       -       0
200 Multi_Zone_Error_Rate   0x0008   200   200   000    Old_age   Offline      -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Completed without error       00%     35012         -
# 2  Extended offline    Completed without error       00%     34988         -
# 3  Extended offline    Completed without error       00%     34964         -
# 4  Extended offline    Completed without error       00%     34940         -
# 5  Extended offline    Completed without error       00%     34919         -
# 6  Extended offline    Completed without error       00%     34892         -
# 7  Extended offline    Completed without error       00%     34868         -
# 8  Extended offline    Completed without error       00%     34845         -
# 9  Extended offline    Completed without error       00%     34821         -
#10  Extended offline    Completed without error       00%     34797         -
#11  Extended offline    Completed without error       00%     34773         -
#12  Extended offline    Completed without error       00%     34749         -
#13  Extended offline    Completed without error       00%     34725         -
#14  Extended offline    Completed without error       00%     34701         -
#15  Extended offline    Completed without error       00%     34677         -
#16  Extended offline    Interrupted (host reset)      10%     34652         -
#17  Extended offline    Completed without error       00%     34628         -
#18  Extended offline    Completed without error       00%     34604         -
#19  Extended offline    Completed without error       00%     34580         -
#20  Extended offline    Completed without error       00%     34556         -
#21  Extended offline    Completed without error       00%     34533         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.